Detail Information
1.  Heating and hot water modes.
2. Heating capacity 11kw, 12kw, 16kw, 18kw, 20kw, 34kw, 40kw.
3. Work at down to -25DegC.
4.  Electronic expansion valve for main circuit and EVI circuit.
5.  Receives ON/OFF signal from thermostat, master controller, smart grilletc to save more energy.
6. Heating curves for more comfortable temperature and more energy-saving.
7. Monobloc type.
8. Copeland scroll EVI compressor.
9. With compressor heater.
10.  With bottom plate heater.
11.  With 3kw back-up electric heater.
12.  With energy class A circulating pump.
13.  With control for 3-way valve to switch between heating circuit and hotwater circuit.
14.  With water flow switch.
15.  We offer OEM service including back-up heater, circulating pump, casingdesign, painting color etc.

Model

 

SHAW-11EVIM

SHAW-12EVIM

Power supply

/

220V/1PH/50Hz

380V/3PH/50Hz

Refrigerant

/

R407C

R407C

Heating capacity 1

KW

10.2

11.2

Heating power input  1

KW

2.30

2.51

COP 1

/

4.43

4.46

Heating capacity 2

KW

7.7

8.8

Heating power input  2

KW

2.40

2.70

COP 2

/

3.21

3.26

Heating capacity 3

KW

5.9

6.7

Heating power input  3

KW

2.40

2.70

COP 3

/

2.46

2.48

Heating capacity 4

KW

5.0

5.7

Heating power input  4

KW

2.30

2.60

COP 4

/

2.17

2.19

Heating capacity 5

KW

8.60

9.50

Heating power input  5

KW

3.57

3.91

COP 5

/

2.41

2.43

Max. water temperature

60

60

Rated water temperature

55

55

Water flow

m3/h

1.70

1.80

Condenser

 

tube-in-shell

tube-in-shell

Water pressure drop

Kpa

22

24

Water connections

Inch

1

1

Built-in water flow switch

 

paddle type

paddle type

Built-in water pump

 

NO

NO

Built-in electric heater

 

NO

NO

Built-in auto air vent

 

NO

NO

Built-in water expansion vessel

 

NO

NO

Compressor

Brand

Copeland (EVI)

Copeland (EVI)

Quantity

1

1

Type of defrosting

/

Reverse circulation

Reverse circulation

Fan quantity

 

1

1

Air flow

m3/h

3250

3250

Fan rated power

W

90

90

Noise

dB(A)

52

52

Net weight

kg

100

110

Gross weight

kg

115

125

Net dimensions

mm

1110*460*850

1110*460*850

Packing dimensions

mm

1175*530*1010

1175*530*1010

 

1. Unit working temperature : -25℃ to 43℃
2. 
1)Test condition: ambient temp: 7℃/6℃, water inlet/outlet: 30℃/35℃
2) Test condition: ambient temp: -2℃/-1℃, water inlet/outlet: 30℃/35℃
3)Test condition: ambient temp: -15℃/-℃, water inlet/outlet: 30℃/35℃
4)Test condition: ambient temp: -20℃/-℃, water inlet/outlet: 30℃
5)Test condition: ambient temp: 7℃/6℃, water inlet: 58℃